Medical

5 essential UX methods for developing safe medical devices

Since medical devices are subject to strict regulation due to the impact they can have on (human) health, their design process should be carried out according to best practices, including human factors. From every detail of the use environment to any possible use error, UX methods feed that process, as recommended by the international standard IEC-62366-1, which details the application of usability engineering to medical devices. Here is an overview of five key UX methods.

1. User interviews

During the initial phase of the project, in order to define the Use Specification, it is critical to gather as much information as possible on each of the user profiles. Individual interviews with patients, doctors, nurses, pharmacists or other healthcare professionals are ideal to get deep insights about the motivations, challenges, learning styles and conceptual models of the people who will actually use the device.
To define the Use Specification, it is also essential to investigate the Use Environment. The resulting design constraints will vary depending on whether the device will be used in an intensive care unit, operating room, consultation office, ambulance, etc. By interviewing users in their workplaces, we gain valuable information on this subject.
Alternative methods can also bring insights on the Use Environment and User Profiles. For example, contextual inquiry combines interviewing with observing the user interacting with an existing device (e.g. a competitive product). Focus groups with several users or a committee of experts is another related method that can be used upstream of the project. These are particularly useful when the solution to design is novel and there is no comparable product on the market.

2. Task analysis

To systematically identify User Interface Characteristics Related to Safety and potential Use Errors, task analysis is the preferred method. In usability engineering, the User Interface not only includes the graphical interface, but also any physical aspect of the device (shape, dimensions, weight, texture, etc.), documentation, training, or anything else that can play a role in how someone interacts with the device.
A detailed task analysis, which is most often presented as a table or a diagram, is therefore essential for thinking about all the aspects of the interface that could affect the safety of users, such as the patient, operator, or anyone else who interacts with the device.
Based on the user’s intention (e.g. administering an intravenous medication), a task is defined (e.g. preparing the device), which is divided into sub-tasks (e.g. setting the dosage) and then into steps. For an even more systematic approach to identifying potential use errors, a PCA task analysis can be performed. Each step is then associated with the three types of interaction, namely Perception, Cognition and Action.
To identify potential use errors for each interaction, factors listed in the Use Specification will also be taken into account. For example, if the operating environment is noisy, the possibility that the operator will not hear an audible alarm will be considered. Or, if the nurse who uses a device is tired because they work long hours at night, they may read the displayed data incorrectly.
The task analysis, along with the list of potential use errors, will feed into the User Interface Specifications, also known as design requirements.

3. Prototyping

In addition to being useful to communicate User Interface Specification within the project team, mockups and prototypes are an essential tool for Formative Evaluations.
Early in the design process, before a single line of code is written, static graphical mockups can be given to users to get feedback on the usability of a control display. Likewise, a wood or 3D-printed prototype of a device can be given to users to find out about its ergonomics.
Based on a trial-and-error approach, these preliminary representations of the User Interface are key to get user feedback and adapt the solution accordingly.

4. Expert evaluations

To assess the usability of a medical device prior to involving users, UX specialists have a few tools at their disposal: heuristic assessment and cognitive walkthrough. The first consists of methodically analyzing the graphical interface of a system, page by page, based on a series of established criteria called heuristics. Several sets of criteria can structure such an analysis, such as the Ergonomic Criteria of Bastien and Scapin and the 10 usability heuristics by Jakob Nielsen.

Nielsen's 10 Usability Heuristics

As for cognitive walkthrough, it means that the UX specialist, based on the available information about the user, task and context, performs a task as the user. They can then detect certain weaknesses of the system.
These expert-based methods can be used on the early mockups or prototypes of a new device or to evaluate existing devices. They can be used in the first Formative Evaluation rounds of a usability engineering process. They typically cast light on obvious problems (low-hanging fruit) and lead to them getting fixed prior to usability testing. Although expert-based methods are rather simple and quick to use — at least when you have access to experts — it is important to keep in mind that they have the major weakness of not being based on the experience of the users!

5. Usability testing

User testing (or usability testing) is a crucial method for Formative Evaluation and Summative Evaluation. In short, it consists of asking potential users to perform tasks with a prototype or finished product and observing them interacting with the device. It provides precious access to what the user actually does, and, during a debriefing session following the test, to what the user says about their experience. These sessions yield valuable insights about how to improve the design.
Depending on the project stage and constraints, usability testing is flexible, as far as the protocol and prototype go. It can be held remotely or in person, in a conference room or in a simulated medical environment, and with preliminary mockups or with a realistic prototype. The objective of a test can be to evaluate a specific aspect of a device or the overall experience.

During the Summative Evaluation — which aims to get objective evidence of the safety of use following the development process — it is crucial to mimic the actual user experience as closely as possible. At that point, we will use the final product in a realistic setting, and participants will be representative of the target users.

Finally, keep in mind that an optimal usability engineering process implies that all evaluations are planned prior to the design and development steps. The objectives, protocol and timing of each Formative Evaluation, as well as the Summative Evaluation, should be detailed in an Evaluation Plan.

NEW EBOOK

Demystify the design process with 7 frequently asked questions about UX

From dynamic sketches to immersive role-playing, every discipline have to be involved in this UX approach focused on creating unforgettable interactions 🚀
Discover our insights and elevate your UX design process by downloading our free ebook!

Sources

Lallemand, C., Méthodes de design UX, Groupe Eyrolles, 2018.
IEC 62-62366-1: 2015 Application of usability engineering to medical devices
IEC 62-62366-2: 2016 Guidance on the application of usability engineering to medical devices

Author & collaborators

Written by
UX Team

Newsletter & Monthly Digest

Subscribe to get our insights delivered to your email inbox.

Other posts you may like

Events

MedTech Conference 2024: See You in Toronto

Software

Enhancing Medical Device Cybersecurity with the STRIDE Threat Model

News

SoundBite’s Console Innovative Design Gets Gold Certification at the 2024 Grands Prix du Design

Events

MedTech Conference 2024: See You in Toronto

Software

Enhancing Medical Device Cybersecurity with the STRIDE Threat Model